3,551 research outputs found
Disproportionation Phenomena on Free and Strained Sn/Ge(111) and Sn/Si(111) Surfaces
Distortions of the Sn/Ge(111) and Sn/Si(111) surfaces
are shown to reflect a disproportionation of an integer pseudocharge, ,
related to the surface band occupancy. A novel understanding of the
-1U (``1 up, 2 down'') and 2U (``2 up, 1 down'') distortions of
Sn/Ge(111) is obtained by a theoretical study of the phase diagram under
strain. Positive strain keeps the unstrained value Q=3 but removes distorsions.
Negative strain attracts pseudocharge from the valence band causing first a
-2U distortion (Q=4) on both Sn/Ge and Sn/Si, and eventually a
-3U (``all up'') state with Q=6. The possibility of a
fluctuating phase in unstrained Sn/Si(111) is discussed.Comment: Revtex, 5 pages, 3 figure
Ge-substitutional defects and the r3xr3 <--> 3x3 transition in alpha--SnGe(111)
The structure and energetics of Ge substitutional defects on the
alpha-Sn/Ge(111) surface are analyzed using Density Functional Theory (DFT)
molecular dynamics (MD) simulations. An isolated Ge defect induces a very local
distortion of the 3x3 reconstruction, confined to a significant downwards
displacement (-0.31 A) at the defect site and a modest upward displacement
(0.05 A) of the three Sn nearest neighbours with partially occupied dangling
bonds. Dynamical fluctuations between the two degenerate ground states yield
the six-fold symmetry observed around a defect in the experiments at room
temperature. Defect-defect interactions are controlled by the energetics of the
deformation of the 3x3 structure: They are negligible for defects on the
honeycomb lattice and quite large for a third defect on the hexagonal lattice,
explaining the low temperature defect ordering.Comment: 4 pages, Revtex, 7 Encapsulated Postscript figures, uses epsf.sty.
Submitted to Phys. Rev. Let
New Techniques in Diagnostic X-ray Imaging: A Simulation Tool and Experimental Findings
Abstract Absorption X-ray imaging is a well-established technique. However it is still a challenging task in its search for a compromise between the need for high spatial resolution and high contrast and the request to keep the dose delivered to the patient within acceptable values. New imaging techniques are under investigation, like the use of new X-ray sources, phase contrast imaging or K-edge imaging. Monte Carlo or analytic simulations are often the best way to test and predict the effectiveness of these techniques. A new simulation tool for X-ray imaging will be presented together with some applications to the characterization of new X-ray sources, in-line phase contrast effect and angiographic K-edge imaging. Simulation results will be compared also with experimental dat
Phase transitions in two dimensions - the case of Sn adsorbed on Ge(111) surfaces
Accurate atomic coordinates of the room-temperature (root3xroot3)R30degree
and low-temperature (3x3) phases of 1/3 ML Sn on Ge(111) have been established
by grazing-incidence x-ray diffraction with synchrotron radiation. The Sn atoms
are located solely at T4-sites in the (root3xroot3)R30degree structure. In the
low temperature phase one of the three Sn atoms per (3x3) unit cell is
displaced outwards by 0.26 +/- 0.04 A relative to the other two. This
displacement is accompanied by an increase in the first to second double-layer
spacing in the Ge substrate.Comment: RevTeX, 5 pages including 2 figure
A Study of Charged P-wave D Meson Production in Semileptonic B Decays
A Study of Charged P-wave D Meson Production in Semileptonic B Decays. A search for the semileptonic decay of B mesons into final states involving charged D** as well as non resonant D0-pi is performed in a sample of approximately 3 million hadronic Z decays recorded with the ALEPH detector at LEP. Topological vertex criteria are used to separate the B -> D**+ l nu X signal from background as well as to search for the non-resonant component B -> D0 pi l nu X. Preliminary results for the branching fraction into resonant and non-resonant components are presented
FIRST experiment: Fragmentation of Ions Relevant for Space and Therapy
Nuclear fragmentation processes are relevant in different fields of basic research and applied physics and are of particular interest for tumor therapy and for space radiation protection applications. The FIRST (Fragmentation of Ions Relevant for Space and Therapy) experiment at SIS accelerator of GSI laboratory in Darmstadt, has been designed for the measurement of different ions fragmentation cross sections at different energies between 100 and 1000 MeV/nucleon. The experiment is performed by an international collaboration made of institutions from Germany, France, Italy and Spain. The experimental apparatus is partly based on an already existing setup made of the ALADIN magnet, the MUSIC IV TPC, the LAND2 neutron detector and the TOFWALL scintillator TOF system, integrated with newly designed detectors in the interaction Region (IR) around the carbon removable target: a scintillator Start Counter, a Beam Monitor drift chamber, a silicon Vertex Detector and a Proton Tagger for detection of light fragments emitted at large angles (KENTROS). The scientific program of the FIRST experiment started on summer 2011 with the study of the 400 MeV/nucleon 12C beam fragmentation on thin (8mm) carbon targe
New Techniques in Diagnostic X-ray Imaging: A Simulation Tool and Experimental Findings
AbstractAbsorption X-ray imaging is a well-established technique. However it is still a challenging task in its search for a compromise between the need for high spatial resolution and high contrast and the request to keep the dose delivered to the patient within acceptable values. New imaging techniques are under investigation, like the use of new X-ray sources, phase contrast imaging or K-edge imaging. Monte Carlo or analytic simulations are often the best way to test and predict the effectiveness of these techniques. A new simulation tool for X-ray imaging will be presented together with some applications to the characterization of new X-ray sources, in-line phase contrast effect and angiographic K-edge imaging. Simulation results will be compared also with experimental dat
Phase Contrast Imaging Using a Single Picosecond X-ray Pulse of the Inverse Compton Source at the Bnl Accelerator Test Facility
Inverse Compton scattering (ICS) X-ray sources are of current interest due to their novel features that enable new methods in medical and biological imaging. As a compelling example of such a possibility, we present an experimental demonstration of single shot inline phase contrast imaging using the ICS source located at the BNL Accelerator Test Facility. The phase contrast effect is clearly observed in the images obtained. Further, its qualities are shown to be in agreement with the predictions of theoretical models through comparison of experimental and simulated images of a set of plastic wires of differing composition and size. We also display an example of application of the technique to single shot phase contrast imaging of a biological sample
Modulations of glycerophosphorylcholine and phosphorylcholine in Friend erythroleukemia cells upon in vitro-induced erythroid differentiation: a 31P NMR study
AbstractA 31P NMR study has been carried out on Friend erythroleukemia cells (FLC) induced to undergo erythroid differentiation in vitro. Significant levels of glycerophosphorylcholine (GroPCho) and phosphorylcholine (P-Cho) were identified both in the untreated cells and in their PCA extracts. In FLC treated 4 days in vitro with either dimethylsulfoxide (DMSO) or hexamethylenebisacetamide (HMBA), the intracellular concentration of P-Cho was markedly increased, whereas that of GroPCho appeared to be significantly reduced. HMBA was more effective than DMSO in producing this effect. The concomitant modulations of GroPCho and P-Cho in differentiated FLC suggest the hypothesis that erythroid differentiation involves modifications of the regulatory mechanisms controlling biosynthesis and catabolism of phospholipids
- …